EMC Testing
Electromagnetic compatibility (EMC) is the branch of electrical sciences which studies the unintentional generation, propagation and reception of electromagnetic energy with reference to the unwanted effects (Electromagnetic Interference, or EMI) that such energy may induce. The goal of EMC is the correct operation, in the same electromagnetic environment, of different equipment which use electromagnetic phenomena, and the avoidance of any interference effects.
In order to achieve this, EMC pursues two different kinds of issues. Emission issues are related to the unwanted generation of electromagnetic energy, and to the countermeasures which should be taken in order to reduce such generation and to avoid the escape of any remaining energies into the external environment. Susceptibility or immunity issues, in contrast, refer to the correct operation of electrical equipment in the presence of unplanned electromagnetic disturbances.
Interference, or noise, mitigation and hence electromagnetic compatibility is achieved by addressing both emission and susceptibility issues, i.e., quieting the sources of interference, making the coupling path between source and victim less efficient, and making the potential victim systems less vulnerable
EMC test items and fee
|
Test Item
|
parameter
|
Standard
|
Fee
|
Conducted Emission-Mains Ports
|
9KHz-30MHz
|
EN 55022, EN 55013,EN55014-1,EN55015,EN55011,
EN 61000-6-3, EN 61000-6-4, FCC PART 15
|
|
Conducted Emission-Telecommunications Ports
|
150KHz-30MHz
|
EN 55022
|
|
Conducted Emission-Click
|
150KHz-30MHz
|
EN55014-1
|
|
Conducted Emission-Insertion Loss
|
150KHz-1605KHz
|
EN55015
|
|
Disturbance Power
|
30MHz-300MHz
|
EN 55013, EN 55014-1
|
|
Radiated Electromagnetic Disturbances
|
9KHz-30MHz
|
EN 55015
|
|
Radiated Emission
|
9KHz-30MHz
|
EN 55011,EN 55025,FCC PART 15, EN 301 489
|
|
Radiated Emission
|
30MHz-1GHz
|
EN 55022, EN 55013, EN 55014-1, EN 55015, EN 55011, EN 61000-6-3, EN 61000-6-4, FCC PART 15, EN 301 489
|
|
Radiated Emission
|
1GHz-26.5 GHz
|
EN 55013, EN 55022, EJN 55011, FCC PART 15, EN 301 489
|
|
Current Harmonics
|
Class a, b, c d
|
IEC 61000-3-2
|
|
Voltage fluctuations and Flicker
|
Rating Current ≤16A
|
IEC 61000-3-3
|
|
Electrostatic Discharge
|
±2KV--±25 KV
|
IEC 61000-4-2
|
|
Radiated, radio-frequency, electromagnetic field immunity
|
Level:1---30V/m
Frequency Range:
80MHz-1GHz
|
IEC 61000-4-3
|
|
Radiated, radio-frequency, electromagnetic field immunity
|
Level:1---30V/m
Frequency Range:
1GHz -6GHz
|
IEC 61000-4-3
|
|
Electrical Fast Transients/Burst immunity
|
±0.25KV--±8KV
|
IEC 61000-4-4
|
|
Surge immunity
|
Level: ±0.5KV--±8KV
|
IEC 61000-4-5
|
|
Surge immunity
|
Level: ±8KV --±20KV
|
IEC 61000-4-5
|
|
Conducted disturbances, induced by radio-frequency field immunity-Mains port
|
1V—10V
|
IEC 61000-4-6
|
|
Conducted disturbances, induced by radio-frequency field immunity- Telecommunications Ports
|
1V—10V
|
IEC 61000-4-6
|
|
Power frequency magnetic field immunity
|
1A/m--100 A/m
|
IEC 61000-4-8
|
|
Voltage dips, short interruptions and voltage variations immunity
|
0%--100%
|
IEC 61000-4-11
|
|
S1-Immunity test for the antenna input connector
|
|
EN 55020
|
|
S2 a-Immunity test for the audio connectors& ac mains power connectors
|
|
EN 55020
|
|
S2 b-Immunity test for RF voltage (common mode) at antenna terminal
|
|
EN 55020
|
|
S3/S6-Immunity against radiated fields
|
|
EN 55020
|
|
S4-Test for screening effectiveness
|
|
EN 55020
|
|
S5-Test for keyed carrier
|
|
EN 55020
|
|
|