简体中文 English
Position: Home > Test Service >

EMC Testing

 Electromagnetic compatibility (EMC) is the branch of electrical sciences which studies the unintentional generation, propagation and reception of electromagnetic energy with reference to the unwanted effects (Electromagnetic Interference, or EMI) that such energy may induce. The goal of EMC is the correct operation, in the same electromagnetic environment, of different equipment which use electromagnetic phenomena, and the avoidance of any interference effects.

  In order to achieve this, EMC pursues two different kinds of issues. Emission issues are related to the unwanted generation of electromagnetic energy, and to the countermeasures which should be taken in order to reduce such generation and to avoid the escape of any remaining energies into the external environment. Susceptibility or immunity issues, in contrast, refer to the correct operation of electrical equipment in the presence of unplanned electromagnetic disturbances.

  Interference, or noise, mitigation and hence electromagnetic compatibility is achieved by addressing both emission and susceptibility issues, i.e., quieting the sources of interference, making the coupling path between source and victim less efficient, and making the potential victim systems less vulnerable

EMC test items and fee
Test Item
parameter
Standard
Fee
Conducted Emission-Mains Ports
 
9KHz-30MHz
EN 55022, EN 55013,EN55014-1,EN55015,EN55011,
EN 61000-6-3, EN 61000-6-4, FCC PART 15
 
Conducted Emission-Telecommunications Ports
 
150KHz-30MHz
EN 55022
 
Conducted Emission-Click
150KHz-30MHz
EN55014-1
 
Conducted Emission-Insertion Loss
150KHz-1605KHz
EN55015
 
Disturbance Power
30MHz-300MHz
EN 55013, EN 55014-1
 
Radiated Electromagnetic Disturbances
9KHz-30MHz
EN 55015
 
Radiated Emission
9KHz-30MHz
EN 55011,EN 55025,FCC PART 15, EN 301 489
 
Radiated Emission
30MHz-1GHz
EN 55022, EN 55013, EN 55014-1, EN 55015, EN 55011, EN 61000-6-3, EN 61000-6-4, FCC PART 15, EN 301 489
 
Radiated Emission
1GHz-26.5 GHz
EN 55013, EN 55022, EJN 55011, FCC PART 15, EN 301 489
 
Current Harmonics
Class a, b, c d
IEC 61000-3-2
 
Voltage fluctuations and Flicker
Rating Current ≤16A
IEC 61000-3-3
 
Electrostatic Discharge
±2KV--±25 KV
IEC 61000-4-2
 
Radiated, radio-frequency, electromagnetic field immunity
Level:1---30V/m
Frequency Range:
80MHz-1GHz
IEC 61000-4-3
 
Radiated, radio-frequency, electromagnetic field immunity
Level:1---30V/m
Frequency Range:
1GHz -6GHz
IEC 61000-4-3
 
Electrical Fast Transients/Burst immunity
±0.25KV--±8KV
IEC 61000-4-4
 
Surge immunity
Level: ±0.5KV--±8KV
IEC 61000-4-5
 
Surge immunity
Level: ±8KV --±20KV
IEC 61000-4-5
 
Conducted disturbances, induced by radio-frequency field immunity-Mains port
1V—10V
IEC 61000-4-6
 
Conducted disturbances, induced by radio-frequency field immunity- Telecommunications Ports
1V—10V
IEC 61000-4-6
 
Power frequency magnetic field immunity
1A/m--100 A/m
IEC 61000-4-8
 
Voltage dips, short interruptions and voltage variations immunity
0%--100%
IEC 61000-4-11
 
S1-Immunity test for the antenna input connector
 
EN 55020
 
S2 a-Immunity test for the audio connectors& ac mains power connectors
 
EN 55020
 
S2 b-Immunity test for RF voltage (common mode) at antenna terminal
 
EN 55020
 
S3/S6-Immunity against radiated fields
 
EN 55020
 
S4-Test for screening effectiveness
 
EN 55020
 
S5-Test for keyed  carrier
 
EN 55020